• Sealed Indoor AC High Voltage Vacuum Circuit Breaker 10kv 11kv 24kv (vcb)
  • Sealed Indoor AC High Voltage Vacuum Circuit Breaker 10kv 11kv 24kv (vcb)
  • Sealed Indoor AC High Voltage Vacuum Circuit Breaker 10kv 11kv 24kv (vcb)
  • Sealed Indoor AC High Voltage Vacuum Circuit Breaker 10kv 11kv 24kv (vcb)
  • Sealed Indoor AC High Voltage Vacuum Circuit Breaker 10kv 11kv 24kv (vcb)

Sealed Indoor AC High Voltage Vacuum Circuit Breaker 10kv 11kv 24kv (vcb)

Breaking Capacity: High Voltage Circuit Breakers
Operation: Energy-storage Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Draw-out
Structure: Vcb
Customization:

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
VB4
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Customized by Relay Protection
Certification
ISO9001-2000, Type Test
Transport Package
Wooden Case
Specification
Embeded pole
Trademark
Farady
Origin
P. R. China
HS Code
8535210000
Production Capacity
1000unit/Month

Product Description

Sealed Indoor AC High Voltage Vacuum Circuit Breaker 10kv 11kv 24kv (vcb)

12/24kV-1250A-31.5kA indoor drawable type embeded pole vacuum circuit breaker(vcb)
Description
VB4 series medium voltage vacuum circuit-breakers with lateral operating mechanism feature the separate pole construction technique.
VB4 vacuum circuit breakers have been designed for indoor use and air insulated switchboards.
Their switching capacity is sufficient to handle any conditions arising from switching of equipment and system components under normal operating and fault conditions, particularly short-circuits, within the parameters of their technical data. The vacuum circuit-breakers of type VB4, designed in column form, can be supplied both as individual units for fixed installation and mounted on chassis. Vacuum circuit-breakers are characterized by their simple and robust construction. They have a long life expectancy. There is no adverse effect on the vacuum, even from frequent switching of operating and short-circuit currents.
 
Advantages
Vacuum circuit-breakers have particular advantages for use in networks where there is a high switching frequency in the working current range and/ or where a certain number of short- circuit breaking operations are expected. VB4 vacuum circuit-breakers are suitable for auto reclosing and have exceptionally high operating reliability and long life. The circuit- breakers are notable for their compact design, small dimensions together with high capacity. The operating mechanisms have a low maintenance requirement and the interrupters are maintenance- free throughout their service lives. They are well suited to all load breaking operations which occur in practice, and in particular:
Short-circuit currents;
Overhead lines under load and, no-load conditions;
Cables under load and no-load conditions;
Transformers under load and no-load conditions;
Generators under load and no-load conditions;
Ripple control system;
Capacitor banks(also parallel switching) and Motors with starting currents above 600A;
 
Application

Cable control and protection
Overhead control and protection
Transformers and distribution substations
Motor and transformer control and protection
Generator control and protection
Capacitor bank control and protection

Main characteristics
Rated voltage1) kV 12 24 • / •• / •
• / •• / •
• / •• / •
• / •• / •
• / •• / •
• / •• / •
• / •• / •
• / •• / •
• / •• / •
••
••
Rated frequency Hz 50 -60 50 - 60
Rated normal current   630...40002) 630.25
Rated short-circuit breaking current (symm.) kA 16.31.5 40 50 63 16.31.5
Rated short-circuit making current kA 40.8 100 1254) 158 40.8
Rated duration of short-circuit4) s 3 3 3 3 3
Fixed- / withdrawable Version   • / • • / • • / • • / - • / •
Max. overall dimensions
(fixed Version)
mm
p
H
a
b
c
150-275
205-310
450-700
424 
461-5996)
210-275
310
570-700
424
5996)
210-275
310
600-750
459
6088)
275
310
750
459
677
210-275
310
570-700
424
631-661
Weight kg 73-105 94-180 147-260 265 100-110
Embedded Pole    
Assembled Pole          

1) Test voltage according IEC62271-100
2) 4000 A with forced cooling
3) 3150 A with forced cooling in APG technology
4) Higher values on request
5) 360 mm for fixed, 280 mm for withdrawable Version
6) Circuit-breaker with heat sink 616 mm
7) Withdrawable Version
8) Circuit-breaker with heat sink 634 mm


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
108880000 RMB
Management System Certification
ISO 9001, ISO 14001