• 0.4kv/12kv/24kv/36kv Switchgear/ Switchboard/ Electrical Cubicle/ Sf6 Ring Main Unit
  • 0.4kv/12kv/24kv/36kv Switchgear/ Switchboard/ Electrical Cubicle/ Sf6 Ring Main Unit
  • 0.4kv/12kv/24kv/36kv Switchgear/ Switchboard/ Electrical Cubicle/ Sf6 Ring Main Unit
  • 0.4kv/12kv/24kv/36kv Switchgear/ Switchboard/ Electrical Cubicle/ Sf6 Ring Main Unit

0.4kv/12kv/24kv/36kv Switchgear/ Switchboard/ Electrical Cubicle/ Sf6 Ring Main Unit

Certification: ISO9001, Type Tested
Shell Material: Steel Plate
Voltage Level: Medium Voltage
Installation: Fixed
Structure: Floorstanding
Current: AC
Samples:
US$ 2200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
RMU
Transport Package
Wooden Case
Specification
12/24KV-630A
Trademark
Farady
Origin
P. R. China
HS Code
85371090
Production Capacity
1000unit/Month

Product Description

++++General
HXGN15-12/24 unit type air insulated ring main unit with SF6 load switch as main switch, for whole cabinet is suitable for electric distribution automation and compact also expandable metal close switchgear. It characters in its simple structure, flexible operation, reliable interlocking and convenient installation etc., which can provide the satisfactory technical projects both for different application occasions and users. With the adoption of sensor technology and the protection relay up to date, plus the advanced technology and flexible assembly project, HXGN15-12/24 unit type SF6 RMU can completely meet the requirement of continuously variable market. It can take self-produced FLS-12/24 load break switch; also according to user's demand can be assembled with the internationally top-ranking brand LBS or VCB, Operational methods for the main switch inside ring main unit can be either manual or electric power driven. And It can meet the requirement of "Four Controls" when matched with FTU and RTU.  
0.4kv/12kv/24kv/36kv Switchgear/ Switchboard/ Electrical Cubicle/ Sf6 Ring Main Unit
++++Service enviromenet a) Air temperature: Maximum temperature: +40ºC; Minimum temperature:-5ºC 
b) Humidity: Monthly average humidity 95%; Daily average humidity 90% . 
c) Altitude above sea level: Maximum installation altitude: 2000m 
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. 
e) No frequent violent shake  
++++Units for all functions
1. Incoming unit with switch disconnector(Load break switch) schemas With other extra components optional 2. Outgoing unit with Fuse-switch protection schemas With other extra components optional 3.Incoming/outgoing circuit breaker protection schemas With other extra components optional
4. MV metering schemas With other extra components optional
5. Casings (Bus bar Panel) schemas With other extra components optional
6. Others
For Distribution switchboard schema  
1. Switch disconnector   


Switch unit (375/500 mm) 
Switch unit (500 mm) 
Switch unit-with/ without earthing switch -right or left outgoing line (375 mm)  
Note: Extra components for example lightning arresters or lower earthing switch is optional.  
2. Fuse-switch protection  
  
Fuse-switch-combinati on unit (375/500 mm) 
Fuse-switch-combination unit (625 mm) 
Fuse-switch-combination unit -right or left outgoing line (375 mm)  
Note: Extra components for example lightning arresters or zero sequence CT is optional. 
3. Circuit-breaker protection  
  
Single-isolation circuit breaker unit(750 mm) 
Single-isolation circuit breaker unit  right or left outgoing line (750 mm)  
Note: 1. For HV SF6 circuit breaker also with many types can be selected. It Is according to client's requirement . ( SF1/Schneider, LNR/Rockwill, PF/Areva, etc.) Also Vacuum circuit breaker is also optional.(VD4/S-12/24 or VSC-12/24) 2. Other extra components for example Zero sequence CT is considering after communicated by our company.  
4. MV metering  
  Voltage transformers for mains with earthed neutral system (375/500 mm) Current and/or voltage measurement unit (750 mm)  
Note: Extra components for example lightning arresters or zero sequence CT is optional.  
  
5. Casings (Bus bar Panel)  
   
Connection unit Right/left outgoing line(375 mm) 
Incoming cable-connection unit(375 mm) 
Incoming cable-connection unit(500 mm)  
Note: Other extra components is optional (Disconnecting switch panel, Voltage transformer panel, etc.)  
6. Other auxiliary schemas  
   
Disconnector unit (375/500 mm) 
MV/LV transformer unit for auxiliaries(375 mm) 
Busbar earthing compartment(375 mm)    
  
++++Main technical specifications 
0.4kv/12kv/24kv/36kv Switchgear/ Switchboard/ Electrical Cubicle/ Sf6 Ring Main Unit


Note: For short circuit breaking and peak current is based on Fuse plus combination.  

Send your message to this supplier

*From:
*To:
avatar Mr. Benliao Zheng
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
108880000 RMB
Management System Certification
ISO 9001, ISO 14001